OVERVIEW
Emergency panel light is a lamp specially designed for emergency lighting. It is usually combined with the normal lighting system. When the power supply is interrupted or an emergency occurs, it can automatically switch to emergency lighting mode to provide necessary lighting; emergency panel light follows The indirect lighting design of the previous generation is elegant and classic, while the appearance has been improved and is slimmer.
Available in sizes of 300×300mm, 600×600, 300×1200 and 600x1200mm (customized products), the maximum system efficiency is 130 lumens/watt. Enables quick and easy installation and is suitable for applications where air outlets are required for office lighting fixtures. Completely indirect lighting design can provide a comfortable visual experience in the office area.
PRODUCT
Product performance of Queendom emergency panel light at test current Tj=25°C
PRODUCT | RANK NO. | NOMINAL λd(CCT) | PRODUCT SIZE (mm) | POWER(W) | VOLTAGE (VF/V) | FLUX (lm) | EFFECT (LM/W) | CRI (Ra) | TYPICAL DEG | EMERGENCY TIME | CHARGING TIME | PART NUMBER | |
LED POWER | EMERGENCY POWER | ||||||||||||
EPSE3030S118WA2 | ESL0311 | 2700K | 300×300×30mm | 18 | 3±1 W | 110/220 | 1950 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL031 |
EPSE3030S118VA2 | ESL0312 | 3000K | 300×300×30mm | 18 | 3±1 W | 110/220 | 1950 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL032 |
EPSE3030S118TA2 | ESL0313 | 4000K | 300×300×30mm | 18 | 3±1 W | 110/220 | 1950 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL033 |
EPSE3030S118RA2 | ESL0314 | 5000K | 300×300×30mm | 18 | 3±1 W | 110/220 | 1950 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL034 |
EPSE3030S118PA2 | ESL0315 | 6000K | 300×300×30mm | 18 | 3±1 W | 110/220 | 1950 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL035 |
EPSE0312S138WA2 | ESL0316 | 2700K | 300×1200×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL036 |
EPSE0312S138VA2 | ESL0317 | 3000K | 300×1200×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL037 |
EPSE0312S138TA2 | ESL0318 | 4000K | 300×1200×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL038 |
EPSE0312S138RA2 | ESL0319 | 5000K | 300×1200×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL039 |
EPSE0312S138PA2 | ESL0320 | 6000K | 300×1200×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL040 |
EPSE3060S124WA2 | ESL0321 | 2700K | 300×600×30mm | 24 | 3±1 W | 110/220 | 2400 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL041 |
EPSE3060S124VA2 | ESL0322 | 3000K | 300×600×30mm | 24 | 3±1 W | 110/220 | 2400 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL042 |
EPSE3060S124TA2 | ESL0323 | 4000K | 300×600×30mm | 24 | 3±1 W | 110/220 | 2400 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL043 |
EPSE3060S124RA2 | ESL0324 | 5000K | 300×600×30mm | 24 | 3±1 W | 110/220 | 2400 lm | 100-130LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL044 |
EPSE3060S124PA2 | ESL0325 | 6000K | 300×600×30mm | 24 | 3±1 W | 110/220 | 2400 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL045 |
EPSE6060S138WA2 | ESL0326 | 2700K | 600×600×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL046 |
EPSE6060S138VA2 | ESL0327 | 3000K | 600×600×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL047 |
EPSE6060S138TA2 | ESL0328 | 4000K | 600×600×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL048 |
EPSE6060S138RA2 | ESL0329 | 5000K | 600×600×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL049 |
EPSE6060S138PA2 | ESL0330 | 6000K | 600×600×30mm | 38 | 3±1 W | 110/220 | 3600 lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL050 |
EPSE0612S172WA2 | ESL0331 | 2700K | 600×1200×30mm | 72 | 3±1 W | 110/220 | 7200lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL051 |
EPSE0612S172VA2 | ESL0332 | 3000K | 600×1200×30mm | 72 | 3±1 W | 110/220 | 7200lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL052 |
EPSE0612S172TA2 | ESL0333 | 4000K | 600×1200×30mm | 72 | 3±1 W | 110/220 | 7200lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL053 |
EPSE0612S172RA2 | ESL0334 | 5000K | 600×1200×30mm | 72 | 3±1 W | 110/220 | 7200lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL054 |
EPSE0612S173PA2 | ESL0335 | 6000K | 600×1200×30mm | 72 | 3±1 W | 110/220 | 7200lm | 110-140LM/W | 80↑ | 120 | ≥180min | ≥12h | 9405500000ESL055 |
FEATURES
Automatic switching: When the main power supply is interrupted, the emergency panel lights can automatically switch to emergency lighting mode without manual operation.
Long-lasting lighting: Emergency panel lights are usually equipped with large-capacity batteries that can provide long-term emergency lighting to ensure continuous operation in emergency situations.
High efficiency and energy saving: Using high-efficiency light sources such as LED, it has lower energy consumption and longer service life.
Safe and reliable: The lamp design complies with safety standards, and the outer casing is made of fireproof, waterproof, dustproof and other materials to ensure that it can work normally in harsh environments.
BENEFITS
Quick response: Emergency panel lights can be activated in a very short time to provide timely lighting for evacuation and rescue in emergencies.
Energy saving and environmental protection: Using LED light source, it not only has high brightness, but is also energy-saving and environmentally friendly, reducing energy consumption.
Easy maintenance: The emergency panel light has a simple structural design, easy maintenance, and reduced usage costs.
Safe and reliable: In emergencies such as fires, emergency panel lights can maintain stable operation and provide key lighting for personnel evacuation.
APPLICATION
Emergency panel lights are widely used in various public places and key facilities, such as shopping malls, hospitals, schools, office buildings, subway stations, etc. In these places, emergency panel lights are usually installed in key locations such as corridors, stairwells, and safety exits to ensure that sufficient lighting can be provided in an emergency to help personnel quickly evacuate and conduct rescue operations.